General InformationTripp Lite 3 phase Metered PDU / Power Distribution Units offer real-time local reporting of current levels in amps via set of 3 built-in digital meters. Enables visual monitoring of PDU current levels to preserve proper loading balance and prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.Additional Product SpecificationsFull Product Specifications: Click to viewTechnical InformationInput Receptacles: NEMA L21-30POutput Receptacles: 36 x IEC 60320 C13Output Receptacles: 9 x IEC 60320 C19Protection Type: Overload ProtectionPower DescriptionInput Voltage: 208 V ACOutput Voltage: 208 V ACPower Rating: 8600 VAInput Current: 24 APhysical CharacteristicsForm Factor: Vertical RackmountForm Factor: Toolless-mountRack Height: 0UHeight: 70"Width: 2.7"Depth: 2.2"Weight (Approximate): 13.50 lbMiscellaneousPackage Contents: Metered PDU3MV6L2130A 45-Outlets PDUCord Retention Sleeves (36 C14, 9 C19)Spare Installation Buttons (2 9mm / 4 6mm)Rack Mounting BracketsOwner's ManualEnvironmentally Friendly: YesEnvironmental Certification: RoHSWarrantyLimited Warranty: 2 Year
PDU TypeMetered Output Capacity Details8.6kW (208V) total capacity 13.9A max per output phase (L1-L2, L2-L3, L3-L1), 12A max per C13 outlet Frequency Compatibility50 / 60 Hz Output Receptacles(36) C13, (9) C19 Output Nominal Voltage208 Overload Protection3 20A double-pole circuit breakers (1 per output phase) PDU Input Voltage208 Recommended Electrical Service30A 208V with NEMA L21-30R outlet Maximum Input Amps24 PDU Plug TypeNEMA L21-30P Input Cord Length (m) 1.83 Input Phase3-Phase Reported Load SegmentsSupports local monitoring of current for each output phase (13.8A balanced max per output load bank L1-L2, L2-L3 and L3-L1) Outlets are color coded and labelled for phase and load bank identification L1-L2 feeds black outlets L2-L3 feeds dark-gray outlets L3-L1 feeds light-gray outlets Front Panel LCD DisplaySet of 3 digital current meters report output current per phase Front Panel LEDsn/a Switchesn/a Material of ConstructionMetal Form Factors SupportedVertical rackmount installation supported with included mounting brackets supports toolless mounting in button-mount compatible racks PDU Form FactorVertical (0U) Storage Temperature Range5 to 122F (-15 to 50C)
Tripp-Lite PDU PDU3MV6L2130A 8.6kW 3-Phase Metered 208V 36xC13/9xC19 Retail